User’s Guide MultiMaster™ Digital MultiMeter Series With PC Interface Models: MM560A MM570A A
10 MM560A-MM570A-EU-EN V1.1 8/12 Resistance, Continuity functions Press SELECT button momentarily t
11 MM560A-MM570A-EU-EN V1.1 8/12 Capacitance, Diode test function Press SELECT button momentarily
12 MM560A-MM570A-EU-EN V1.1 8/12 other readings indicate the diode is resistive or shorted (defective).
13 MM560A-MM570A-EU-EN V1.1 8/12 A, mA, A, and %4-20mA Current functions Insert the red test lead into t
14 MM560A-MM570A-EU-EN V1.1 8/12 PC-COMM computer interface capabilities The instrument equips with an op
15 MM560A-MM570A-EU-EN V1.1 8/12 Backlighted display Press the SELECT button for 1 second or more to turn
16 MM560A-MM570A-EU-EN V1.1 8/12 5) MAINTENANCE WARNING To avoid electrical shock, disconnect the meter
17 MM560A-MM570A-EU-EN V1.1 8/12 Battery and Fuse replacement Battery use: 9V alkaline battery NEDA1604
18 MM560A-MM570A-EU-EN V1.1 8/12 6) SPECIFICATIONS Display: 4-4/5 digits 50,000 counts. Selectable stab
19 MM560A-MM570A-EU-EN V1.1 8/12 Power Supply: Single Alkaline 9V battery; NEDA1604A, JIS6AM6 or
2 MM560A-MM570A-EU-EN V1.1 8/12 1) SAFETY This manual contains information and warnings that must be foll
20 MM560A-MM570A-EU-EN V1.1 8/12 Electrical Specifications Accuracy is (% reading digits + number of dig
21 MM560A-MM570A-EU-EN V1.1 8/12 AC & AC+DC Voltage RANGE MM570A MM560A Accuracy* 20Hz -- 45Hz 2
22 MM560A-MM570A-EU-EN V1.1 8/12 DC Current RANGE Accuracy Burden Voltage 500.00A 0.15%+20d 0.15mV/A 5
23 MM560A-MM570A-EU-EN V1.1 8/12 Thermocouple range & accuracy not included Hz Line Level Frequency
24 MM560A-MM570A-EU-EN V1.1 8/12 ISO-9001 Certified
3 MM560A-MM570A-EU-EN V1.1 8/12 WARNING To reduce the risk of fire or electric shock, do not expose this
4 MM560A-MM570A-EU-EN V1.1 8/12 3) PRODUCT DESCRIPTION Panel Illustration A1234567 1) 5-4/5 d
5 MM560A-MM570A-EU-EN V1.1 8/12 Average sensing RMS calibrated RMS (Root-Mean-Square) is the term use
6 MM560A-MM570A-EU-EN V1.1 8/12 cause digit rolling or offset in voltage measurements. This series has a
7 MM560A-MM570A-EU-EN V1.1 8/12 A A ADCVACVHz Note: Line Level Frequency measuring function input sen
8 MM560A-MM570A-EU-EN V1.1 8/12 Hz Logic Level Frequency and % Duty Cycle functions Press SELECT butto
9 MM560A-MM570A-EU-EN V1.1 8/12 T1-T2 Dual Channels Temperature function (MM570A only) Press SELECT butto