Seite 1 - Mini Digital Multimeter

User's Guide Mini Digital Multimeter Model MN15A A

Seite 2 - Introduction

MN15A V1.1 02/09 10 General Specifications Diode Test Bias voltage: 2.8VDC typical Continuity Check Audible signal will sound if the resistanc

Seite 3 - Controls and Jacks

MN15A V1.1 02/09 11  Support line (781) 890-7440 Technical support: Extension 200; E-mail: [email protected] Repair & Returns: Extension 2

Seite 5

MN15A V1.1 02/09 2Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers AC/DC Voltage, AC/DC Current, R

Seite 6

MN15A V1.1 02/09 3Controls and Jacks 1. LCD display 2. Rotary function switch 3. 10 ampere test lead jack 4. Test lead jack for voltage, mill

Seite 7

MN15A V1.1 02/09 4Operating Instructions WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be

Seite 8 - Maintenance

MN15A V1.1 02/09 5DC CURRENT MEASUREMENTS CAUTION: Do not make current measurements at 10 Amps for longer than 30 seconds. Exceeding 30 seconds

Seite 9 - Range Specifications

MN15A V1.1 02/09 6RESISTANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors

Seite 10 - General Specifications

MN15A V1.1 02/09 7BATTERY VOLTAGE TEST CAUTION: Do not measure batteries while they are installed in the devices they are powering. The batteri

Seite 11 - Warranty

MN15A V1.1 02/09 8Maintenance WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the back c

Seite 12 - MN15A V1.1 02/09

MN15A V1.1 02/09 9Range Specifications Function Range Resolution Accuracy DC Voltage (V DC) 200mV 0.1mV ±(0.5% reading + 2 digits) 2000mV 1mV 2